What was found
DURING C-09 CHECK 3 EACH CRACKS WERE FOUND AT FASTENER HOLES ON CABIN FLOOR SUPPORT ANGLE BETWEEN BS 1200 TO BS 1210, BL 0. MAINTENANCE REMOVED CRACKED FLOOR SUPPORT ANGLE AT BS 1200 TO BS 1210, BL 0; FABRICATED A NEW REPLACEMENT ANGLE; INSTALLED REPAIR PART IAW B757-200 SRM 53-00-51, PG 214-215 FIG 204.