What was found
DURING C-15 CHECK CORROSION WAS FOUND ON UPPER SURFACE OF LT AFT LAVATORY SUB FLOOR SHEAR WEB BETWEEN BS 1016 AND BS 1029, LBL 5-15, WL 208. MAINTENANCE REMOVED CORRODED SUB FLOOR SHEAR WEB BETWEEN BS 1016 AND BS 1029, LBL 5-24; FABRICATED A NEW REPLACEMENT SHEAR WEB PER DWG 65C32707; INSTALLED REPAIR PART IAW B737-300 SRM 51-40-02, PG 1.