What was found
DURING C-15 CHECK EXFOLIATION CORROSION WAS FOUND ON UPPER SURFACE OF LT AFT LAVATORY SUB FLOOR STRAP BETWEEN BS 1017 AND BS 1028, LBL 3, WL 208. MAINTENANCE REMOVED CORRODED SUB FLOOR SHEAR WEB BETWEEN BS 1017 AND BS 1028, LBL 3, WL 208; FABRICATED A NEW REPLACEMENT SHEAR WEB PER DWG 65C32677; INSTALLED REPAIR PART IAW B737-300 SRM 53-60-51, FIG 101.