What was found
LCQ - MAJOR REPAIR - DURING C-12 CHECK A 3 INCH CRACK WAS FOUND ON CABIN FLOOR INTERCOSTAL BS 780-800, BL-0. MAINTENANCE REMOVED CRACKED INTERCOSTAL BS 780-800, BL-0-; FABRICATED A REPAIR ANGLE; INSTALLED REPAIR PART IAW B757-200 SRM 53-00-51, FIG 204, PG 214-215.