What was found
MCN - MAJOR REPAIR - DURING C-13 CHECK GALVANIC CORROSION WAS FOUND ON UPPER SURFACE OF FLOOR SUPPORT (INTERCOSTAL) BETWEEN BS 950 AND BS 959, RBL 46, WL 208. MAINTENANCE REMOVED DAMAGED INTERCOSTAL BETWEEN BS 950 AND BS 959, RBL 46, WL 208; FABRICATED A NEW REPLACEMENT INTERCOSTAL PER 65C33367; INSTALLED REPAIR PARTS IAW B737-300 SRM 51-40-02 FIG 12.