What was found
DURING C-8 CHECK EXFOLIATION CORROSION WAS FOUND ON FLOORBEAM Y1292 L/H, FORWARD OF FR 68. MAINTENANCE CUTOUT CORRODED SECTION OF L-2 DOOR SILL FLOORBEAM Y1292 LT FROM FR 67 TO FR 69; PERFORMED HFEC INSPECTION OF CUTOUT; FABRICATED AN ANGLE AND SHIM; INSTALLED REPAIR PARTS IAW A320 SRM 53-41-14, FIG. 201.