What was found
MAJOR REPAIR, DURING C-15 CHECK, A .5000 INCH CRACK WAS FOUND IN FLOORBEAM AT FASTENER HEAD IN WEB BS 700, LBL 24.5, WL 204. MAINTENANCE CUTOUT DAMAGED SECTION OF FLOOR BEAM WEB AT BS 700, LBL 24.5, WL 204; FABRICATED A NEW REPLACEMENT SECTION OF WEB AND A REINFORCING DOUBLER; INSTALLED REPAIR PARTS IAW AWA E R 03-5702-04184-ES2A.