What was found
MAJOR REPAIR, DURING C-15 CHECK A .6250 INCH CRACK WAS FOUND IN FLOORBEAM AT FASTENER HEAD IN WEB BS 705, LBL 24.5, WL 204. MAINTENANCE CUTOUT DAMAGED SECTION OF FLOORBEAM WEB AT BS 705, LBL 24.5, WL 204; FABRICATED A NEW REPLACEMENT SECTION OF WEB AND A REINFORCING DOUBLER; INSTALLED REPAIR PARTS IAW AWA E.R. 03-5702-04184-ES2A.