What was found
LAX - EEL - DURING 4-DAY CHECK EMERGENCY ESCAPE PATH LIGHTS AT SEAT ROWS 3, 6, 12, 16, AND 20 WERE FOUND INOPERATIVE. AIRCRAFT MAINTENANCE FERRIED TO LAS, MAINTENANCE REPAIRED EMERGENCY LIGHT WIRING AT CONNECTOR 7260VCS SEAT ROW 12, ALSO REPLACED EMERGENCY POWER SUPPLY UNIT (12WL); OPERATIONAL CHECK OF EMERGENCY LIGHTING WAS GOOD.