What was found
MCN - MAJOR REPAIR - DURING C-19 CHECK CORROSION WAS FOUND ON FLOORBEAM AT BS 986, BETWEEN LBL 25 AND LBL 31, WL 208. MAINTENANCE REMOVED UPPER CHORD OF FLOORBEAM AT BS 294, FROM LBL 51 TO RBL 10; FABRICATED A NEW REPLACEMENT SECTION OF UPPER CHORD; INSTALLED REPAIR PART IAW B737-300 SRM 53-00-51 FIG 202.