What was found
3 SHARP JOLTS OCCURRED IN YAW APPROX 45 SEC TO 1 MIN APART. AFTER 2ND JOLT RECEIVED ECAM INDICATION NR 1 GEN FAULT, AFTER 3RD JOLT ECAM INDICATED AUTO/FLT YAW DAMP NR 1 INOP, DIVERTED, LANDED W/O EVENT. MX ISSUED MELS. YAW DAMP NR 1 INOP. NR 1 IDG INOP. MX INSPECTED NR 1 GEN FEEDER CABLES FOR POSSIBLE ARCING, NO DEFECTS NOTED. R & R NR 1 ENG IDG. FOUND APU GEN SWITCH NOT LATCHING, REPLACED PUSH BUTTON SWITCH PER ESPM, OPS CK GOOD. IDG CONFIRMED REASON FOR REMOVAL. TEARDOWN OF UNIT FOUND GENERATOR MAIN STATOR WINDING SHORTED WITH A HOLE BLOWN THROUGH IT, THIS CONDITION WOULD CERTAINLY RESULT IN AN OFF LINE TRIP, REMOVED AN REPLACED GENERATOR MAIN STATOR.