What was found
DURING C-15 CHECK, A 1/8 INCH CRACK WAS FOUND IN R-1 DOOR AFT FRAME AT 3RD DOOR STOP CUTOUT FROM THE BOTTOM BS 328, STR 14 RT. MAINTENANCE BLENDED OUT CRACK, MATERIAL LOSS WITHIN LIMITS IAW B737-300 SRM 52-10-02, FIG 101. PERFORMED HFEC INSPECTION OF BLEND OUT TO ENSURE NO CRACKS EXIST, TREATED AREA.