What was found
MCN - MAJOR REPAIR - DURING C-18 CHECK A 1 INCH CRACK WAS FOUND ON LOWER FLOORBEAM STRAP AT BS 330.5, LBL 44, WL 201. MAINTENANCE REMOVED FASTENERS IN REPAIR AREA AND DRILLED A STOP DRILL HOLE AT END OF CRACK BS 330.5, LBL 44; FABRICATED A REPAIR PLATE PER DWG 65-45834; INSTALLED REPAIR PART IAW B737-300 SRM 53-10-51 FIG 204.