What was found
MCN - MAJOR REPAIR - DURING C-18 CHECK CORROSION WAS FOUND ON LOWER SURFACE OF FLOOR SUPPORT UPPER OUTBOARD LEG BETWEEN BS 950 AND BS 960, RBL 46, WL 208. MAINTENANCE REMOVED CORRODED FLOOR SUPPORT AT RBL 46, FROM BS 950 TO BS 960; FABRICATED A NEW REPLACEMENT FLOOR SUPPORT PER DWG 65C10592; INSTALLED REPAIR PART IAW B737-300 SRM 51-40-02.