Service difficulty report · Bleed Valve · Airbus A320231

Difficulty date
January 7, 2005
Submitted
January 10, 2005
Operation
Air carrier
Aircraft
N626AW
Make and model
Airbus A320231
Aircraft serial
65
Aircraft time
49,440 hours, 22,105 cycles
Engine
Iae V2500A1
Part
Bleed Valve
Part number
5950041108
Part serial
0430
Condition
Malfunctioned
Location
Nr 1 Engine
Part time
12,844 hours, 5,185 cycles
Stage of operation
CL
How discovered
O
Nature of condition
P
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CLIMBOUT 8000 FT LOUD BANG LT SIDE, ALL ENG IND NORM. TURNED BACK. A SECTION OF NR 1 ENG I/B C-DUCT INNER LINER FOUND MISSING IN AREA OF 10TH STAGE BLEED VALVE. FOUND SMALL DENT IN L/E OF STAB 10 INCHES FROM OB END. R&R LT HORIZONTAL STAB END CAP, NR 1 ENG LT TRANSLATING SLEEVE ASSY, NR 1 ENG RT IB TR. FOUND NR 1 ENG NOZZLE ASSY DAMAGED. REPLACED COMMON NOZZLE ASSY, CKS GOOD. REPLACED 10TH STAGE BLEED VALVE & SOLENOID VALVE, CKS GOOD. THRUST REVERSER AND SLEEVE WERE REPAIRED IAW ROHR/IAE V2500 CMM 78-30-00 REV. 12. THE 10TH STAGE SOLENOID VALVE WAS FOUND TO FAIL SOLENOID PULL IN TEST ON "B" COIL. NO TROUBLE WAS FOUND WITH THE 10TH STAGE BLEED VALVE AT VENDOR