What was found
MCN - MAJOR REPAIR - DURING C-17 CHECK, EXFOLIATION CORROSION WAS FOUND ON UPPER AND LOWER SURFACE OF FLOOR SUPPORT AT BS 956, BETWEEN RBL 26 AND RBL 40, WL 208. MAINTENANCE REMOVED CORRODED FLOOR SUPPORT AT BS 956, FROM RBL 26 TO RBL 40; FABRICATED A NEW REPLACEMENT FLOOR SUPPORT PER DWG 65C10592; INSTALLED REPAIR PARTS IAW B737-300 SRM 51-40-02.