As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
SAL - MAJOR REPAIR - DURING BC-4 CHECK EXFOLIATION CORROSION WAS FOUND AROUND FASTENER HOLES ON SILL BEAM AT BULK CARGO DOOR FR 62+3 INCHES, STR 38 RT. MAINTENANCE CUTOUT DAMAGED SECTION OF SILL BEAM AT BULK CARGO DOOR FR 62+3 INCHES, STR 38 RT; FABRICATED A FILLER AND DOUBLER; INSTALLED REPAIR PARTS IAW A320 SRM 53-41-49 FIG 203.