What was found
MCN - MAJOR REPAIR - DURING C-19 CHECK, A 5/8 INCH CRACK WAS FOUND IN R-2 DOOR CUTOUT AT FASTENER HOLE IN THE FORWARD LOWER CORNER BS 961, STR 17 RT. MAINTENANCE TRIMMED OUT DAMAGE IN SKIN AT R-2 DOOR CUTOUT IN FORWARD LOWER CORNER BS 961, STR 17 RT; FABRICATED A FILLER, 2 EACH DOUBLERS, AND A TRIPLER; INSTALLED REPAIR PARTS IAW ER 03-5300-05111-ES1.