What was found
MCN - MAJOR REPAIR - DURING C16 CHECK FOUND SEVERAL SUB-STRUCTURES DAMAGED ON THE L1 FOWARD ENTRY DOOR CUTOUT SURROUND STRUCTURES. INTERCOSTAL CLIP AT SILL, LOCATED AT BS 350 AND STRINGER 16 RT, CRACKED .30 INCHES IN LENGTH. MAINTENANCE REMOVED CRACKED INTERCOSTAL CLIP AT BS 350, STR 16R. FORMED CLIP IAW AMERICA WEST AIRLINES ENGINEERING REQUEST 03-5301-05193-SS2. PREPPED NEW ANGLE FOR INSTALLATION AT BS 350, STR 16R, SILL IAW AWA ER 03-5301-05193-SS2. INSTALLED FABRICATED REPAIR PARTS AT SILL BS 350 AND STR 16 IAW AWA ER 03-5301-05193-SS2.