What was found
DURING C15 CHECK, DISCOVERED FLOOR STRAP CRACKED, 2.0 INCHES IN LENGTH, ON THE BOTTOM OF BS 328 BEAM AT BL 11L. MAINTENANCE STOP DRILLED CRACK ON FLOORBEAM AT BS 328, BL 11L IAW BOEING 737-300 SRM 53-10-51-2 FIG 204. FABRICATED REPAIR PLATE AND INSTALLED ON FLOOR STRAP LOCATED AT BOTTOM OF BS 328 BEAM AT BL 11L IAW BOEING 737-300 SRM 53-10-51-2 FIG 204.