What was found
MCN - DURING C15 CHECK DISCOVERED FLOOR STRAP CRACKED, .7 INCHES IN LENGTH, ON THE BOTTOM OF BS 344 BEAM AT BL 45L. MAINTENANCE STOP DRILLED CRACK ON FLOORBEAM AT BS 344, BL 45L IAW BOEING 737-300 SRM 53-10-51-2 FIG 204. FABRICATED REPAIR PLATE AND INSTALLED ON FLOOR STRAP LOCATED AT BOTTOM OF BS 344 BEAM AT BL 45L IAW BOEING 737-300 SRM 53-10-51-2 FIG 204.