What was found
MCN - DURING C16 CHECK, DISCOVERED EXFOLIATION CORROSION, LEVEL TWO, ON THE UPPER FLOOR STRAP FROM BS 1009 TO BS 1029, BL 3L AND WL 208. FOUND CORROSION TO BE OUT OF LIMITS IAW BOEING 737-300 SRM 51-10-02-0G FIG 1. REMOVED UPPER FLOOR STRAP FROM BS 1009 TO BS 1029, BL 3L AND WL 208 IAW BOEING 737-300 SRM 51-40-02-0G FIG 8. FABRICATED STRAP IAW BOEING 737-300 SRM 51-40-02-0G FIG 1. INSTALLED FABRICATED REPAIR PARTS AT BS 1009 TO BS 1029, BL 3L AND WL 208 IAW BOEING 737-300 SRM 51-40-02-0G FIG 3.