What was found
GYR - DURING C10 CHECK, DISCOVERED FLOORBEAM AT BS 345, WL 208.10 AND BL 60R CORRODED. MAINTENANCE REMOVED CORROSION AND FOUND TO BE OUT OF LIMITS. CUT OUT AND REMOVED FLOORBEAM AT STA 345, WL 208.10 AND BL 60R IAW BOEING 757-200 SRM 53-00-51. FABRICATED CHORD, ANGLES AND STRAPS IAW BOEING 757-200 SRM 53-00-51 FIG 201. INSTALLED FABRICATED REPAIR PARTS AT BS 345, WL 208.1 AND BL 60R IAW BOEING 757-200 SRM 53-00-51 FIG 201.