What was found
MAJOR REPAIR - DURING C19 CHECK DISCOVERED CORROSION ON THE R2 INNER CHORD FROM BS 969-996, FROM WL 208-209 AND RBL 50. MAINTENANCE FOUND CORROSION TO BE OUT OF LIMITS IAW SRM 53-60-15-1A1 FIG 101. REMOVED AND INSTALLED NEW INNER CHORD FROM BS 969 TO BS 996, FROM WL 208 TO WL 209 AND BL 50R IAW SRM 51-40-02-0G FIGS 3, 4, 6, 8, 9 AND 12.