What was found
CREW REPORTED THAT AT FL 360, THE CAPT WINDSHIELD OUTER PANE SHATTERED & LT WINDSHIELD ANTI-ICE FAILED. LANDED WITHOUT FURTHER EVENT. MX R & R CAPT WINDSHIELD & NR 1 WINDSHILED HEAT COMPUTER. OPS CHECKS GOOD. PERFORMED FUNCTIONAL TESTS OF CAPT WINDSHIELD HEAT COMPUTER, NO FAULT FOUND. INSPECTED IAW SAGEM CMM 30-42-36 REV ORIG. CAPT WINDOW SCRAPPED AT VENDOR. INITIAL OBSERVATION OF UNIT REVEALED MOISTURE INGRESS. WINDOW WAS HIGH TIME UNIT, 7 YEARS OLD. CONSIDERED NORMAL FAILURE SEQUENCE FOR AGE OF WINDOW.