What was found
PHX - EEL - DURING 8 DAY DISCOVERED EMERGENCY EXIT LIGHT AT ROW 27 INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY AND POWER SUPPLY, OPS CHECKS WERE GOOD, BATTERY; PN 2013-1A; MFG RADIANT ILLUM; SN UNK.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - EEL - DURING 8 DAY DISCOVERED EMERGENCY EXIT LIGHT AT ROW 27 INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE BATTERY AND POWER SUPPLY, OPS CHECKS WERE GOOD, BATTERY; PN 2013-1A; MFG RADIANT ILLUM; SN UNK.