What was found
DURING CRUISE CREW REPORTED BOTH CSD GENERATOR DRIVE LOW OIL PRESSURE LIGHTS ILLUMINATED IN FLIGHT. CREW COMPLIED WITH QRH AND SECURED BOTH CSD'S. CREW RETURNED TO PHX AND LANDED WITHOUT FURTHER EVENT. MAINTENANCE REMOVED AND REPLACED THE P5-5 GENERATOR DRIVE AND STANDBY POWER MODULE IAW BOEING 737-300 MM 24-21-52-4. OPS CHECKS GOOD. CONFIRMED FAILURE OF UNIT. DURING TEARDOWN FOUND OVERHEATED RESISTORS AND COLD SOLDER JOINTS IN CONTROL BOARDS. WIRING WAS REWORKED DUE TO OVERHEATED CONNECTIONS IN POWER RESISTORS. UNIT OVERHAULED, REPAIRED, AND TESTED IAW BOEING OHM 31-10-66 REV 29.