What was found
DURING TAKEOFF ROLL RECEIVED AVIONICS SKIN AIR VALVE FAULT & AN ECAM MESSAGE STATING NOT TO CLIMB ABOVE 10,000 FT. RETURNED & LANDED WITHOUT EVENT. MX R & R SKIN AIR OUTLET VALVE, 22HQ, IAW MM . OPS CHK GOOD. TEARDOWN CONFIRMS FAULT. ON ENTRY TEST, VALVE FAILED TO SHUTOFF DUE TO ELEC STOP OPEN. VALVE TRAVELED UNTIL STOPS CONTACTED & ACT TORQUE LIMITER SLIPPED. ACT NOISY DURING OPS. AFTER DIASSEMBLY, ELEC STOP SWITCH FOUND NOT DEPRESSED DOWN ENOUGH FOR PROPER CONTACT. ACT TRAVELED UNTIL STOPS CONTACTED. REPLACED CONSUMABLES, IDLE GEAR & OVERHAULED ACT. UNIT CLEANED, SWITCH ADJUSTED, IDLE GEAR REPLACED & ACTUATOR TESTED IAW CMM.