As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
PHX - EEL - CREW REPORTED THAT THREE EMERGENCY EXIT LIGHTS, ONE AT DOOR R2, DOOR L2 AND BETWEEN LAV'S, WERE INOPERATIVE. CREW WAS ABLE TO RE-LIGHT THEM BY CYCLING THE "NO SMOKING" SWITCH BUT THEN THE LIGHTS WENT OUT AGAIN. MAINTENANCE REMOVED AND REPLACED THE POWER SUPPLY 13WL AND DEU 300RH5. OPERATIONAL CHECKS WERE NORMAL IAW TASK CARD R1C33303.