What was found
MCN - DURING C 16 CHECK DISCOVERED CRACKED INTERCOSTALS, 2.2 INCHES, FWD PIT DOOR CUTOUT AT BUS 492 TO 500 AT STR 24 R. MAINTENANCE REMOVED CRACKED INTERCOSTAL FWD PIT DOOR CUTOUT AT BUS 492 TO 500, STIR 24 R. FABRICATED NEW INTERCOSTAL FOR FWD PIT DOOR AND INSTALLED INTERCOSTAL FOR FWD PIT DOOR CUTOUT AT BUS 492 TO 500, STR 24R YAW BOEING DIG 65-20723, SUM 51-40-05-0G FIG 2.