What was found
DURING C16, DISCOVERED SEVERAL SUB-STRUCTURES FOUND CRACKED ON L1 FWD ENTRY DOOR CUTOUT SURROUND STRUCTURES. AREAS PART OF AD 2005-20-03 & REQUIRED OEM REPAIR DISPOSITION. MX REMOVED CRACKED INTERCOSTAL SHEAR TIE, CRACKED .700 INCHES, AT BS 294.5 AND STR 1LL & INSTALLED NEW INTERCOSTAL SHEAR TIE IAW AWA ER NR 03-5300-06084-DF5.