As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GYR - DURING C08 CHECK DISCOVERED LEVEL 2 GALVANIC CORROSION ON FLOORBEAM AT BS 1681 ON LOWER SURFACE OF UPPER CHORD BL 48R TO BL 48L AT WL 208. MAINTENANCE FOUND CORROSION REWORK OUT OF LIMITS. FABRICATED REPAIR ANGLE IAW AWA ER 19-5365-06084-DF1. INSTALLED FABRICATED REPAIR PARTS AT BS 1681 FROM BL 48R TO BL 48L AT WL 208 IAW AWA ER 19-5365-06084-DF1.