As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
GYR - DURING C12 CHECK DISCOVERED ONE SQUARE INCH DELAMINATION AREA ON TOP SURFACE OF NR 7 L/E SLAT 28 INCHES FROM OB EDGE. MAINTENANCE CUT OUT DAMAGED AREA. FABRICATED FILLER AND DOUBLER. BONDED FABRICATED PARTS TO TOP SURFACE OF NR 7 L/E SLAT 28 INCHES FROM OB EDGE IAW SRM 57-43-02-01 ITEM 9 AND SRM 51-70-10-2R PAR 4.