What was found
PHX - EEL - DURING OVERNIGHT INSPECTIONS MAINTENANCE REPORTED THAT THE EMERGENCY LIGHTS AT ROWS 9R, 11R, 13L, 17L, 21L AND AFT ENTRY DOORS WERE INOPERATIVE. MAINTENANCE REMOVED AND REPLACED THE MID CABIN RT EPSU AND THE AFT LEFT OVERHEAD EPSU IAW AMWEST TASK CARD R1C33303 AND A1C33302. OPERATIONAL CHECKS WERE GOOD.