What was found
PHX - LINE MAINTENANCE, DISCOVERED DURING 4 DAY CHECK, 2 INCH FUSELAGE CRACK, 10 INCHES AFT OF RT WING TO BODY EMERGENCY EXIT LIGHT. MAINTENANCE REPAIRED 2 INCH SKIN CRACK AT STA 727E, STR 23R, IAW SRM 53-00-01, 2R REPAIR 31, FIG 201 DETAIL VII AND DETAIL XIX , RE-INSPECT REPAIR AT 60,000 CYCLES AFTER THE REPAIR WAS INSTALLED.