What was found
CABIN FLOOR INTERCOSTAL UPPER ATTACH ANGLE CRACKED, BS 1623 - BS 1634, BL0. REMOVED, FABRICATED AND REPLACED CRACKED CABIN FLOOR INTERCOSTAL UPPER ATTACH ANGLE, BS 1623 - BS 1634, BL0 IAW B757-200 SRM 51-40-02-06 PARAGRAPH 4 FIGURES 3 & 8.