What was found
SAL - FOUND CORROSION AROUND HOLES OF CENTER FITTING SILL OF R1 DOOR, FS 16 + 5, AND FS 20. CENTRAL FITTING SILL OF R1 DOOR BETWEEN FS 16 + 4", AND FS 20 - 4 WAS REPLACED IAW A319 SRM 51-72-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
SAL - FOUND CORROSION AROUND HOLES OF CENTER FITTING SILL OF R1 DOOR, FS 16 + 5, AND FS 20. CENTRAL FITTING SILL OF R1 DOOR BETWEEN FS 16 + 4", AND FS 20 - 4 WAS REPLACED IAW A319 SRM 51-72-11.