As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING OVERNIGHT MAINTENANCE IT WAS DISCOVERED THE EMERGENCY PATH LIGHTING IN ROWS 3 A/B/C AND ROW 15 A/B/C WERE INOP. MAINTENANCE FOUND A BROKEN WIRE IN ROW 15 A/B/C AND A LOOSE WIRE AT THE CONNECTOR IN ROW 3 A/B/C. MAINTENANCE RE-TERMINATED THE WIRE IN BOTH ROWS IAW ESPM 20-48-14. OPS CHECK GOOD.