Service difficulty report · Valve · Airbus A319132

Difficulty date
May 20, 2007
Submitted
May 31, 2007
Operation
Air carrier
Aircraft
N812AW
Make and model
Airbus A319132
Aircraft serial
1178
Aircraft time
26,933 hours, 10,450 cycles
Part
Valve
Part number
1303A000004
Part serial
1124
Condition
Failed
Location
A/C Pack
Part time
24,476 hours, 9,298 cycles
Stage of operation
CL
How discovered
O
Nature of condition
G, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PHL - CREW REPORTED, DURING CLIMB TO F250 PACK 2 TRIPPED. TEMP 32 DEG C ZONE OUTPUT 92 DEG F, PACK FLOW STAYED IN THE LO POSITION. MX REMOVED AND REPLACED NR 2 PACK FLOW CONTROL VALVE PER AMM 21-51-51- 401, OPS/LEAK CHECK WAS GOOD.