What was found
PHX-ABQ - FLT 200 - THE NR 2 INTRANSIT SLAT LIGHT REMAINED ILLUMINATED. FLAPS WERE SELECTED ON APPROACH WITH NR 2 DEVICE ILLUMINATED ON OVERHEAD PANEL. ALL OTHER DEVICES INDICATED FLAPS WERE FULLY EXTENDED. EMERGENCY WAS DECLARED FOR THE NR 2 SLAT NOT FULLY EXTENDING. ACFT LANDED WITHOUT FURTHER PROBLEMS. MX OPS CHECKED LE FLAPS AND SLATS PER BMM 27-810 PG 517. NO FAULTS NOTED. INDICATION SYSTEM PLACED ON UMSR 27-04 CONTROL NR 14315. INDICATION SYSTEM INOP. ACFT RETURNED TO SERVICE. PHX MX REPLACED NR 2 FULL EXTEND SENSOR. MEL REMOVED AND ACFT RETURNED TO SERVICE. (W)