What was found
PHX - FLT 1600 - DURING SCHEDULED INSPECTION, FOUND FLOOR BOARD SUPPORT CORRODED BEYOND CLEAN UP LIMITS, STATION 957 LBL 18 TO LBL 40. REMOVED, FABRICATED AND INSTALLED NEW INTERCOSTAL PER SRM 51-10-02 AND 51-40-02. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - FLT 1600 - DURING SCHEDULED INSPECTION, FOUND FLOOR BOARD SUPPORT CORRODED BEYOND CLEAN UP LIMITS, STATION 957 LBL 18 TO LBL 40. REMOVED, FABRICATED AND INSTALLED NEW INTERCOSTAL PER SRM 51-10-02 AND 51-40-02. (W)