What was found
PHX - FLT 1530 - DURING C7 INSPECTION, FOUND ANGLE INTERCOSTAL CORRODED BEYOND LIMITS AT SCREW HOLES, BS 986 TO 1006 LBL 18. FABRICATED AND INSTALLED INTERCOSTAL PER ER 53-10-01B. (Z)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - FLT 1530 - DURING C7 INSPECTION, FOUND ANGLE INTERCOSTAL CORRODED BEYOND LIMITS AT SCREW HOLES, BS 986 TO 1006 LBL 18. FABRICATED AND INSTALLED INTERCOSTAL PER ER 53-10-01B. (Z)