What was found
DURING SCHEDULED INSPECTION OF TASK C53 107 02, FOUND L1 DOOR INNER CHORD CORRODED BEYOND CLEAN UP LIMITS AROUND SCREW HOLES, STATION 312 TO 340. REMOVED AND REPLACED CHORD PER SRM 51-10-1 AND 51-30-02. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED INSPECTION OF TASK C53 107 02, FOUND L1 DOOR INNER CHORD CORRODED BEYOND CLEAN UP LIMITS AROUND SCREW HOLES, STATION 312 TO 340. REMOVED AND REPLACED CHORD PER SRM 51-10-1 AND 51-30-02. (W)