PHX - DURING SCHEDULED INSPECTION OF TASK C53-107-02, FOUND R1 DOOR INNER CHORD CORRODED BEYOND LIMITS, STATION 294 STR 17. REPLACED CHORD PER SRM 53-10-1 AND 51-30-2. (W)