What was found
PHX - DURING SCHEDULED INSPECTION OF TASK C53 107 02, FOUND TWO AREAS OF CORROSION THAT WERE BEYOND CLEAN UP LIMITS AROUND SCREW HOLES OF STATION 294 FLOOR BEAM, RBL 8 AND RBL 30. REMOVED DAMAGED AREAS OF FLOOR BEAM AND INSTALLED REPAIR TOP CAP AND ANGLES PER SRM 53-10-9. (W)