What was found
PHX - DURING C6 INSPECTION, FOUND FWD ENTRY DOOR INTERCOSTAL SUPPORT ANGLE BETWEEN STA 294 STR 10L AND 11L CRACKED. FABRICATED AND INSTALLED NEW ANGLE PER SRM 51-30-2. (Z)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING C6 INSPECTION, FOUND FWD ENTRY DOOR INTERCOSTAL SUPPORT ANGLE BETWEEN STA 294 STR 10L AND 11L CRACKED. FABRICATED AND INSTALLED NEW ANGLE PER SRM 51-30-2. (Z)