What was found
PHX - DURING ROUTINE MAINTENANCE CHECK, FOUND FLOOR PATH EMERGENCY EXIT LIGHTS INOPERATIVE, ROWS 20 THROUGH 25 AND FROM THE L3 DOOR THROUGH ROW 32. REMOVED AND REPLACED BATTERY ASSEMBLY AT M734, OPS CHECK GOOD. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.