What was found
PHX - DURING C6 INSPECTION, FOUND FLOOR BEAM TO INTERCOSTAL VERTICAL ANGLE CRACKED, BS 660. FABRICATED AND INSTALLED REPLACEMENT ANGLE PER SRM 51-10-00 AND SRM 51-40-02. (W)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING C6 INSPECTION, FOUND FLOOR BEAM TO INTERCOSTAL VERTICAL ANGLE CRACKED, BS 660. FABRICATED AND INSTALLED REPLACEMENT ANGLE PER SRM 51-10-00 AND SRM 51-40-02. (W)