What was found
PHX - DURING ROUTINE MAINTENACNE CHECK, FOUND FLOOR PROXIMITY EMERGENCY EXIT LIGHTS INOPERATIVE FROM ROW 16 THROUGH ROW 20. STRAIGHTENED BENT PINS ON CONNECTOR D3688 AND REPLACED THREE FUSES IN EMERGENCY CHARGERS M1197 AND M1137. OPS CHECK GOOD. (M)