Service difficulty report · Connector · Boeing 7373S3

Difficulty date
June 19, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N313AW
Make and model
Boeing 7373S3
Aircraft serial
23712
Part
Connector
Condition
Dirty
Location
Cooling Fan
Stage of operation
CL
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

ABQ-PHX - FLT 475 - CREW REPORTED THE EQUIPMENT COOLING WAS INOPERATIVE AND ELECTED TO RETURN TO ABQ. CONTRACT MAINTENANCE FOUND EQUIPMENT COOLING NORMAL, THE SUPPLY FAN FAILED. AN UNMANNED STATION RELEASE WAS GIVEN AND THE AIRCRAFT RETURNED TO PHX. UPON ARRIVAL IN PHX, MAINTENANCE CLEANED THE CONNECTOR FOR EQUIPMENT COOLING NORMAL FAN. NO FURTHER DISCREPANCY NOTED. UNMANNED STATION RELEASE REMOVED AND AIRCRAFT RETURNED TO SERVICE. (M)

More about the Boeing 737-3S3